Every NegaWatt project is delivered in full compliance with SANS 1544 — baseline data captured on-site, energy ratings certified, and performance documented with zero assumptions.
Client · EPC Certification
Full Energy Performance Certificate assessment and certification for a G1 multi-storey commercial office building in Johannesburg, conducted under SANS 1544:2014. Building energy consumption was measured, baselined, and benchmarked against the national standard.
Building Old Sappi House · Johannesburg, Gauteng
Energy Performance Assessment conducted per SANS 1544:2014. Building energy consumption measured across all carriers, classified as G1 Commercial, and an Energy Performance Certificate issued with a detailed variance analysis.
203
kWh/(m²·a)
Measured Performance
8,337
m² Building Area
Net Floor
1.69M
kWh Total Energy
Consumption
G1
Building Class
Commercial
Scope & Deliverables
Client · Multi-Building EPC Assessment
NegaWatt completed Energy Performance Certificate assessments across five Fidelity Services Group facilities spanning Gauteng and Western Cape. Each building was assessed individually under SANS 1544:2014, with EPCs issued and registered on the National Building Energy Performance Register (NBEPR).
Fidelity Training Academy
22 Madeline St, Roodepoort, Gauteng
23.13
kWh/(m²·a)
3,565 m²
Gross Floor Area
3,320 m²
Net Floor Area
245 m²
Excluded Area
EPC Issued · SANS 1544:2014
Fidelity Security Robertville
1168 Dommieg St, Robertville, Gauteng
43.34
kWh/(m²·a)
2,535 m²
Gross Floor Area
2,240 m²
Net Floor Area
295 m²
Excluded Area
EPC Issued · SANS 1544:2014
Fidelity Cash Solutions – Hermanstad
518 Van Riebeeck Rd, Hermanstad, Pretoria
82.02
kWh/(m²·a)
1,457 m²
Net Floor Area
Above benchmark of 110 kWh/m²/a
for Energy Zone 5 occupancy class
Performance Context
EPC Issued · SANS 1544:2014
Fidelity Cash Services – Parow
7 Assegaai St, Parow, Cape Town, Western Cape
4,349 m²
Gross Floor Area
2,391 m²
Net Floor Area
1,957 m²
Excluded Area
Energy Zone 4
Climate Zone
EPC Issued · SANS 1544:2014
Fidelity Cash Solutions – Edenvale
14 Freeland Dr, Edenvale, Gauteng
241.61
kWh/(m²·a)
1,157 m²
Net Floor Area
Below benchmark of 90 kWh/m²/a
for Energy Zone 5 occupancy class
Performance Context
EPC Issued · SANS 1544:2014
Client · Municipal Portfolio EPC
NegaWatt served as a subcontractor under Enstain Trading and Projects (Pty) Ltd for the City of Ekurhuleni's building energy performance programme — one of the largest municipal EPC programmes in South Africa. Every assessment was conducted in full compliance with SANS 1544 EPC methodology.
~100
Municipal Buildings Assessed
SANS
1544
Certification Standard
NBEPR
Registration Delivered
Full
Regulatory Compliance
Key Activities
Gathering site-specific data using approved templates — monthly energy usage, maximum demand, facility size, occupancy, equipment types, and usage frequency.
Collaborating with City of Ekurhuleni Customer Care Managers to obtain operational and energy data for each building.
Walkthrough assessments and net floor measurements to confirm buildings met the regulatory threshold of >1,000m² for government-owned structures.
Determining building classification, occupancy, operating hours, and functionality for accurate energy rating benchmarking.
Analysing data to produce energy audit reports and establish reliable consumption baselines for each facility.
Strict adherence to EPC methodology and SANS 1544 standards throughout all assessments — systems assessed included HVAC, water pumping, compressed air, and standby power.